Fluke/Philips-Rubidium Counter/Calibrator (Model PM 6685R)

110
1042
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

With a built-in Rubidium atomic resonance-controlled frequency reference, the PM 6685R is the most accurate frequency counter on the market and it has the additional benefit of full portability.

High stability, high accuracy and short warm-up time make this instrument ideal for high-accuracy calibration procedures outside the calibration laboratory environment, such as in base station transmitters of large telecommunications networks like GSM.

The short warm-up time makes that the PM 6685R is ready for use quickly, for example after transport or change of location inside a building.

High-resolution digital frequency counting

Frequency calibration to relative accuracies of better than 1 part in 108 has traditionally required complicated setups, or have been time-consuming to perform, with frequency counters that needed long measuring times to achieve the required resolution.

With a virtual clock frequency of 4 GHz, Fluke's PM 6685R offers an unmatched resolution of 2.5 x 10-10 per second, giving 10 reliable read-out digits in only one or a few seconds. This makes high-accuracy calibration measurements possible, with the convenience of requiring only a digital counter.

The wide choice of input options allows digital calibration measurements at up to 8 GHz, without the complexity of needing to use synthesizers, mixers and filters to provide the required resolution down to the last digits.

Additionally, digital counting techniques allow a numerical offset or nulling of the display value to make it easy to read changing or arbitrary frequency values with many different digits.

Guaranteed high stability for field operation

The built-in Rubidium reference solves the practical problems of ensuring very high stability under severe field conditions.

The atomic resonance principle of rubidium standards is intrinsically 100 times more stable than an electromechanical crystal resonator; a fact that contributes to making the PM 6685R the most accurate counter/calibrator available for field use.

Also, the atomic reference does not suffer from mechanical, thermal, vibrational and line voltage influences in the way that a crystal oscillator would. When carrying a crystal-based counter, for example, just one small bump against a step can cause more frequency change than several months of aging under controlled calibration laboratory conditions.

This stronger resistance to environmental stress on the reference permits longer calibration intervals in many practical situations, making the PM 6685R more convenient for field personnel and reducing the cost of ownership. In fact, using the PM 6685R at a field site may even reduce the need to send other elements of a field lab out for their own respective calibration.

Rubidium references should therefore be considered for all meaurements or calibrations in the field where accuracies better than a few parts in 108 are required, or where frequent calibration of the counter is not possible.

Resource & Download

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 02873000184 | Fluke/Philips-Rubidium Counter/Calibrator (Model PM 6685R).

Comments are closed.